Is the Juniper SRX345 End of Life? EOL Status, Affected SKUs, and Replacement Options

Follow Us:
Quick Take
The Juniper SRX345 model name alone does not confirm that the entire firewall hardware platform is End of Life. Juniper's current lifecycle information lists several SRX345-related Security Director Cloud software license SKUs as EOL. Check the exact hardware, software, and support SKU before planning a replacement.

If you are managing an SRX345 deployment, the first step is to identify whether the lifecycle concern applies to the firewall hardware, a Junos-related license, or a Security Director Cloud software SKU. This distinction affects support planning, spare-hardware decisions, replacement timing, and migration requirements. You can also review the SRX345 product page before preparing a replacement request.

1. Is the Juniper SRX345 End of Life?
2. Which SRX345 SKUs Are Affected?
3. SRX345 Replacement Options
4. SRX345 Migration Planning Checklist
5. SRX345 EOL and Replacement FAQs

Is the Juniper SRX345 End of Life?

The answer depends on the exact SKU. The Juniper model name “SRX345” can refer to the firewall hardware, a complete system SKU, or a software and security-service license. These products do not necessarily share the same lifecycle dates.

Juniper's official SRX Series lifecycle table lists several SRX345-related Security Director Cloud software license SKUs as End of Life. The current listing identifies the following milestone information:

Lifecycle item Information What it means
Product type Security Director Cloud software license It is not the same as the SRX345 firewall chassis.
Affected license SKUs S-SD-SRX345-S-C-1, S-SD-SRX345-S-C-3, S-SD-SRX345-S-C-5 Verify whether one of these SKUs is installed or included in the current contract.
EOL announced April 15, 2024 The affected software licenses entered the formal EOL process.
Last order date October 15, 2024 The listed last order date has already passed.
End of Support Refer to TSB76687 Confirm the applicable support position for the specific license and contract.

This software lifecycle information does not automatically establish that every SRX345 hardware SKU is EOL. Confirm the exact device label, system SKU, software license, and support contract before deciding whether to replace the firewall.

Which SRX345 SKUs Are Affected?

The most important procurement step is to separate SRX345 software and service licenses from SRX345 hardware and system SKUs.

SKU or SKU family Product type Procurement consideration
S-SD-SRX345-S-C-1 Security Director Cloud software license Check the EOL milestone and replacement management option.
S-SD-SRX345-S-C-3 Security Director Cloud software license Confirm the existing contract and license term.
S-SD-SRX345-S-C-5 Security Director Cloud software license Verify whether the license is still required for the deployment.
SRX345-SYS-JB SRX345 hardware/system SKU Confirm hardware support, software bundle, and power configuration.
SRX345-SYS-JE SRX345 hardware/system SKU Verify the included Junos software and security features.
SRX345-SYS-JB-2AC or SRX345-SYS-JB-DC Power-specific system variants Check dual-AC or DC power requirements before selecting a replacement.

If your current configuration uses the SRX345-SYS-JB system configuration , do not replace it based only on the “SRX345” family name. Confirm the power type, Mini-PIM modules, installed licenses, and required interfaces.

What Does the SRX345 Provide?

The SRX345 is a 1U security gateway designed for distributed enterprise branch deployments. The published hardware configuration includes eight 1GbE RJ-45 ports, eight 1GbE SFP ports, one management port, and four Mini-PIM slots.

The official SRX300 Line Firewall datasheet lists firewall performance of up to 5 Gbps for the SRX345 platform. Review the official SRX345 datasheet before comparing throughput, ports, power, and expansion requirements.

SRX345 Replacement Options

There is no universal one-to-one replacement for every SRX345 deployment. The correct option depends on the firewall role, port requirements, VPN throughput, Mini-PIM usage, power environment, security services, and future capacity requirements.

Option Suitable scenario Checks before selection
Continue with the existing SRX345 The current topology must remain unchanged temporarily. Verify the exact hardware SKU, support contract, software license, and spare requirements.
Evaluate the SRX380 The deployment needs higher port density or 10GbE connectivity. Check 1GbE PoE+ ports, 10GbE SFP+ ports, Mini-PIMs, power, Junos, and chassis-cluster requirements.
Evaluate another SRX platform The current firewall requires higher VPN throughput, more sessions, or a longer-term capacity plan. Compare performance, interfaces, security features, lifecycle, licensing, and migration effort.

Juniper describes the SRX380 platform as a 1U firewall with 16 PoE-enabled 1GbE ports and four 10GbE SFP+ ports. It may be a candidate for deployments that need higher interface density, but it should not be described as an automatic SRX345 successor.

Need an SRX345 lifecycle check?

Send the exact SKU and migration requirements.

SRX345 Migration Planning Checklist

A successful SRX345 replacement requires more than matching the number of Ethernet ports. Complete the following checks before approving a migration design.

1. Record the Exact Hardware and License SKUs

  • Record the chassis label and complete system SKU.
  • Record the software, security-service, and support license SKUs.
  • Document the current Junos OS release and support contract.
  • Confirm whether the device uses single AC, dual AC, or DC power.

2. Map Interfaces and Mini-PIM Modules

  • Document active RJ-45 and SFP interfaces.
  • Record Mini-PIM models and WAN circuit types.
  • List installed optics, cables, and transceivers.
  • Check whether the replacement supports the required interface speed and connector type.
  • Confirm rack depth, airflow, power-feed type, and cable length.

3. Review Security and Routing Features

  • Review NAT, IPsec VPN, OSPF, BGP, VLAN, and Layer 3 routing requirements.
  • Document security policies, application security, URL filtering, and threat-prevention features.
  • Confirm concurrent-session, VPN-throughput, and new-session requirements.
  • Check whether the current deployment uses chassis clustering or high availability.

4. Prepare Configuration, Cutover, and Rollback

  • Back up the current configuration and record interface, routing, VPN, and management settings.
  • Prepare a port-by-port mapping table for the replacement platform.
  • Test security policies, NAT rules, VPN tunnels, and routing behavior before production cutover.
  • Define a maintenance window and rollback configuration.
  • Verify the target Junos release and feature compatibility before migration.

Do not assume that a higher-capacity SRX platform can use the existing configuration without changes. Interface names, security features, license requirements, chassis-cluster settings, and WAN modules may need to be reviewed or reconfigured.

SRX345 EOL and Replacement FAQs

These questions help separate an actual hardware lifecycle issue from a software or licensing lifecycle issue.

Q1 Is the Juniper SRX345 hardware already EOL?
The model name alone is not enough to confirm hardware EOL status. Verify the exact hardware SKU, support contract, and applicable Juniper lifecycle notice.
Q2 Which SRX345 software SKUs are listed as EOL?
The listed SRX345-related Security Director Cloud software SKUs are S-SD-SRX345-S-C-1, S-SD-SRX345-S-C-3, and S-SD-SRX345-S-C-5. Confirm the applicable contract and support position for your deployment.
Q3 Is the SRX380 a direct replacement for the SRX345?
Not automatically. The SRX380 has different port density, 10GbE connectivity, PoE capability, power options, and possible configuration requirements. Evaluate it against the existing deployment.
Q4 Can I continue using an SRX345?
That depends on the exact hardware SKU, support contract, Junos release, and required security services. A software license EOL notice does not automatically answer the hardware support question.
Q5 What information is needed for an SRX345 replacement review?
Prepare the exact SRX345 SKU, quantity, power type, Mini-PIM model, interface requirements, current Junos version, security features, HA requirements, and target migration date.

Final Takeaway

The SRX345 EOL question cannot be answered by the model name alone. First identify whether the affected item is the firewall hardware, a Junos-related license, or a Security Director Cloud software SKU. Then compare replacement platforms by interfaces, Mini-PIMs, power, throughput, security features, software compatibility, and lifecycle requirements.

For a configuration-specific review, you can send your exact SRX345 SKU and migration details for replacement planning and quotation review.