Huawei RH1288 V2 Rack Server

5 2
5/5.0
2 Review(s)
Model: Huawei RH1288 V2 Rack Server
Detail: Huawei RH1288 V2 rack server, Intel Xeon E5-2600 or E5-2600 V2 series CPU, 24 DDR3 DIMMs, RAID, Energy efficiency, 7 hot-swappable fan modules, 2 hot-swappable power supplies
Condition: Brand New Sealed
Shipping:
Express Shipping to United States Ashburn VA,
2-6 Days, via DHL, FedEx, EMS, etc. ?
If you finish the payment today,
your order will arrive within the
estimated delivery time.
US$ 0.00 Brand New Sealed

Ask Our Experts

Live Chat | Email

  • +1-626-239-8066 (USA)
  • +852-3174-6166 (HK)
  • +852-3050-1066 (Fax)
Get Quotes up to
2x Faster
Project Inquiry
Overview

Overview (Huawei RH1288 V2 Rack Server)

Huawei RH1288 V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2*Intel Xeon E5-2600 or Intel Xeon E5-2600 V2 series processors, 24*DDR3 RDIMMs/LRDIMMS slots to support up to 768GB memory capacity, 8*2.5” SAS/SATA HDDs or SSDs or 4*3.5” SAS or SATA HDDSs. This server supports two or four GE ports or two 10 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.

Quick Specs

Figure 1 shows the appearance of Huawei RH1288 V2 Rack Server. The RH1288 V2 has two models:

Figure 1-1 shows the RH1288 V2-8S that supports eight 2.5-inch SAS HDDs, SATA HDDs, or solid-state drives (SSDs).

RH1288 V2-8S

Figure 1-2 shows the RH1288 V2-4L that supports four 3.5-inch SAS or SATA HDDs.

RH1288 V2-4L

Table 1 shows the Quick Specs.

Product

Huawei RH1288 V2 Rack Server

Processors

One or two Intel Xeon E5-2600 or E5-2600 v2 series processors

Memory

24 DDR3 RDIMMs/LRDIMMs

Internal Storage

Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs

RAID Support

● RAID 0, 1, 10, 5, 50, 6, or 60
  ● Supercapacitor
  ● RAID state migration, configuration memory, self-diagnosis, and web-based remote configuration

LOM Network Ports

Network configuration: two or four GE ports or two 10 GE ports

PCIe Expansion

Up to 3 PCIe slots

Fan Modules

Seven hot-swappable fan modules in N+1 redundancy mode
Each fan module consists of two counter-rotating fans.

PSUs

2 hot-swappable PSUs in 1+1 redundancy mode

Management

Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios

Operating Temperature

5ºC to 35ºC (41ºF to 95ºF)

 Product Details

Figure 2 shows the front panel of Huawei RH1288 V2 Rack Server.

Figure 2-1  RH1288 V2-8S front view.

RH1288 V2-8S front view

Note:

 

UID button/indicator

Power button/indicator

 

USB port 1

USB port 2

 

Ethernet port indicator 1

Ethernet port indicator 2

 

HEALTHY indicator

VGA port

 

Disk

⑩ 

Captive screw

 

Hard disk fault indicator

Hard disk active indicator

 

Label (including ESN label)

(Optional) Built-in DVD-ROM driver (only for the RH1288 V2-8S)

 

Hard disk slot label

Figure 2-2  RH1288 V2-4L front view.

RH1288 V2-4L front view

UID button/indicator

Power button/indicator

USB port 1

USB port 2

Ethernet port indicator 1

Ethernet port indicator 2

HEALTHY indicator

Disk

Captive screw

⑩ 

Hard disk fault indicator

Hard disk active indicator

Label (including ESN label)

Hard disk slot label

Figure 3 shows the back panel of Huawei RH1288 V2 Rack Server.

the back panel of Huawei RH1288 V2 Rack Server

Note:

Connection status indicator

GE port 4

Data transmission status indicator

GE port 3

GE port 2

GE port 1

UID indicator

Management network port

USB port 2

⑩ 

USB port 1

VGA port

Serial port

Power socket of PSU 2

PSU 2 indicator

PSU 2

Power socket of PSU 1

PSU 1 indicator

PSU 1

Compare to Similar Items

Table 3 shows the comparison of Huawei RH1288 V2 Rack Server and Huawei RH1288A V2 Rack Server.

Product

Huawei RH1288 V2 Rack Server

Huawei RH 1288A V2 server

Processors

One or two Intel Xeon E5-2600 or E5-2600 v2 series processors

1 or 2 Intel® Xeon® E5-2600 v2 series processors

Memory

24 DDR3 RDIMMs/LRDIMMs

8 DDR3 RDIMMs/LRDIMMs

Internal Storage

Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs

Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs

LOM Network Ports

Network configuration: two or four GE ports or two 10 GE ports

Network configuration: 2 x GE electrical ports

Fan Modules

Seven hot-swappable fan modules in N+1 redundancy mode
Each fan module consists of two counter-rotating fans.

5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans

Get More Information

Do you have any question about the Huawei RH1288 V2 Rack Server?

Contact us now via Live Chat or sales@router-switch.com.

Specification

Specification (Huawei RH1288 V2 Rack Server)

Huawei RH 1288 V2 server Specifications

CPU

The server supports two Intel Xeon® E5-2600 (Sandy Bridge-EP) series CPUs.

One or two CPUs of quad-core, six-core, or eight-core

Highest CPU frequency: 3.3 GHz

Maximum power consumption of each CPU: 135 W

Maximum L3 cache of each CPU: 20 MB

NOTE:

The performance of the 135 W CPU may deteriorate when one fan fails.

The server supports two Intel Xeon® E5-2600 v2 (Ivy Bridge-EP) series CPUs.

One or two CPUs of 4/6/8/10/12 cores

Highest CPU frequency: 3.5 GHz

Maximum power consumption of each CPU: 130 W

Maximum L3 cache of each CPU: 30 MB

NOTE:

The performance of the 130 W CPU may deteriorate when one fan fails.

Two CPUs are connected through two QuickPath buses of full bandwidth. Each link provides a unidirectional transmission rate of up to 8.0 GT/s.

Memory

Maximum number of double data rate 3 (DDR3) DIMMs: 24

Maximum memory capacity: 768 GB

Capacity of a single DIMM: 4 GB, 8 GB, 16 GB, or 32 GB

Memory speed: DDR3 800/1066/1333/1600/1866 MHz

Storage

NOTE:

The total storage capacity of the server is different along with the single hard disk most large-capacity.

The server supports two types of hard disk configurations:

RH1288 V2-8S: supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs at the front.

RH1288 V2-4L: supports four 3.5-inch SAS HDDs or SATA HDDs at the front.

The following information lists the total storage capacity of eight 2.5-inch hard disks:

SAS HDD: 7.2 TB

SATA HDD: 8 TB

SSD: 4.8 TB

The following information lists the total storage capacity of four 3.5-inch hard disks:

SAS HDD: 4 TB

SATA HDD: 16 TB

Hard disks are hot-swappable.

SAS HDDs, SATA HDDs, and SSDs can be installed in one chassis.

The server supports RAID 0, 1, 10, 5, 50, 6, and 60. It supports iBBU battery protection, RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration.

The mainboard can be configured with an Serial Attached SCSI (SAS) card or an SAS RAID controller card (with the maximum 1 GB cache) for improving hard disk storage performance and protecting user data.

RAID controller cards do not occupy standard PCIe slots, which ensures high scalability for the system.

Chipset

Intel® C602 chipset.

Network port

Four types of NICs are supported, providing the following network ports:

Two GE electrical ports, supporting Network Controller Sideband Interface (NCSI), Wake on LAN (WOL), Preboot eXecution Environment (PXE).

Four GE electrical ports, supporting NCSI, WOL, PXE.

Two 10GE optical ports, supporting NCSI, PXE.

Two 10GE electrical ports, supporting NCSI, WOL, PXE.

I/O port

One onboard DVD-ROM/DVD-RW connector

Five USB 2.0 ports: two on the front panel, two on the rear panel, and one on the mainboard

One USB flash port on the mainboard

One VGA port on the front panel for the RH1288 V2-8S and none for the RH1288 V2-4L; one VGA port on the rear panel for either server

One RS232 port on the rear panel

One RJ45 management port on the rear panel

DVD-ROM drive

DVD-ROM/DVD-RW drive, optional when the server is RH1288 V2 (8 hard disks).

Expansion slots

A maximum of three PCIe cards are supported:

One standard PCIe slot of full height and full length

One standard PCIe slot of half height and half length

One non-standard PCIe slot for installing a RAID controller card

The PCIe slots support the Huawei PCIe iNIC to improve the I/O bandwidth and throughput.

The PCIe slots support one Huawei PCIe SSDs for search, cache, and download services to greatly improve the I/O performance.

The PCIe expansion slots support the GPUs, such as Quadro 2000.

Certification

Including CCC, CE, FCC, IC, VCCI, and C-tick

Environmental specifications

Dimensions (H x W x D)

43.6 mm (1 U) x 447 mm x 740 mm (1.72 in. x 17.60 in. x 29.92 in.)

Installation dimensions

The rack server can be installed in a common rack that complies with the IEC 297 standard:

Width: 19 inches

Depth: > 1000 mm (39.37 inches)

Guide rail installation requirements are as follows:

L-shaped guide rail: applies only to Huawei cabinets.

Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm.

Rated power

The rated power for compatible PSUs:

460 W

750 W

800 W

Weight (in full configuration)

Net weight:

Eight 2.5-inch HDDs: 19.6 kg (43.22 lb)

Four 3.5-inch HDDs: 20 kg (44.10 lb)

Packing material weight: 5.3 kg (11.68 lb)

Rated input voltage

AC: 100 to 240 V AC

DC: -48 V DC to -60 V DC

NOTE:

The recommended current specification for the external power circuit breaker connected to the server is 32A.

AC module Emerson 800W-AC(EPW800W-AC) and DC modules not support the high tension directing current.

Temperature

Operating temperature: 5°C to 35°C (41°F to 95°F)

Storage temperature: -40°C to +65°C (-40°F to +149°F)

The temperature change rate is smaller than 20°C (36°F)/h.

Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

Altitude

≤ 3000 m (9842 ft). When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (1.8°F) per 300 m (984.24 ft).

Humidity

Operating humidity: 8% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

The humidity change rate is smaller than 20% RH/h.

Long-term storage humidity: 30% RH to 69% RH (non-condensing)

Acoustic Noise

The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Idle:

LWAd: 6.0 Bels

LpAm: 43.0 dBA

Operating:

LWAd: 6.7 Bels

LpAm: 50.1 dBA

NOTE:

The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

Shipping & Payment

Delivery

Cargo will be delivered within 1 day after payment arrived. Tracking Number will be offered once delivery done.

Delivery OptionsEstimated Delivery Time
DHL 2-4 business days
Fedex 2-4 business days
Hong Kong EMS 5-10 business days
Hong Kong Air Parcel 10-20 business days
By Sea 10-20 business days

Notice:

Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:

Deliver to port:

Router-switch.com is responsible for transporting goods to port. All subsequent customs and transportation fees are the
responsibility of the buyer. Router-switch will recommend trustworthy local freight forwarders to you.Router-switch.com can facilitate the progress under buyer's permission and at buyer's expense.

Deliver to door:

Router-switch.com will quote all destination charge prior once we have confirmed order.
Router-switch.com is responsible for transporting goods to door after you have made the payment.

Payment Methods

Paypal Master Card Visa
Discover American
Express
JCB
Wire Transfer eCheck WestUnion
Warranty

Warranty

100% Low Price Guarantee:

Router-switch.com provides high-quality products at low wholesale prices

All items are ORIGINAL and GENUINE only:

Item conditions are all "New Sealed".
All items are fully tested with working conditions by Huawei certified engineer under customers' permission.

100% Money Back Guarantee:

If your returns meet our relevent standards,you can contact our customer service team to exchange or return any product that you bought from us.

Professional Technical Support:

Router-switch.com experienced technical team can provide support over the phone, by chat, by email or by remotely login.

Flexible Secure Payment & Shipment:

Verified authorization: Mcafee Secure, VeriSign Secured

Return Material Authorization (RMA) Process

Standard Hardware Warranty Policy:

Original new sealed Huawei product: 1 Year.

The Support Contacts:

If your Huawei products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

Reviews

Customer Reviews

5 5
5 (2 reviews)
5 Stars
2
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0

Share your thoughts with other customers?

Posted on 11/10/2016
Verified Buyer
55
a ideal choice for cloud computing

a ideal choice for cloud computing.

Posted on 12/1/2014
Verified Buyer
55
?768GB memory capacity

This Huawei server supports 768GB memory capacity. Well, the memory is just ok.