• مقدمة
  • Plan Guide
  • Recommended Product
  • Comparison

What Is Lossless Ethernet for AI & HPC?

What
  • Lossless Ethernet is a high-performance Ethernet architecture designed to deliver predictable, zero-loss data transport—making it essential for AI training clusters and HPC workloads, where microbursts and transient congestion can quickly cripple GPU and application performance.

    Modern AI and HPC traffic is highly synchronous, bursty, and latency-sensitive. When GPUs exchange gradients or MPI jobs synchronize, even minor packet loss can trigger retransmissions, pipeline stalls, and idle accelerators. Traditional best-effort Ethernet tolerates drops and relies on recovery after the fact; AI and HPC workloads do not. By preventing packet loss under congestion and maintaining deterministic data flow, Lossless Ethernet keeps distributed workloads aligned and GPUs consistently utilized at scale.

Designing Lossless Ethernet for AI & HPC Fabrics

Explore how to architect RoCEv2‑based lossless Ethernet networks for AI training, inference, and HPC clusters, with focus on PFC, ECN, QoS, and leaf–spine design to achieve deterministic latency and zero‑loss performance at scale.

Designing
  • Key Requirements for RoCEv2 Lossless Fabrics

    Lossless Ethernet for AI and HPC starts with a clear understanding of workload and traffic patterns, including all‑to‑all GPU east‑west flows, storage access, and control traffic. Architects must define latency and throughput targets, oversubscription ratios, and failure domains before selecting hardware. Critical baseline capabilities include support for RoCEv2, priority‑based flow control (PFC), ECN/RED, hierarchical QoS, and deep buffers sized for microburst absorption. A well‑planned leaf–spine topology with consistent MTU, deterministic hop count, and non‑blocking or low‑oversubscription links is essential to keep training jobs stable and predictable.

    Define Your Fabric Requirements
Designing
  • Configuring PFC, ECN, and QoS for Zero‑Loss Transport

    Once the requirements are defined, the next step is to translate them into consistent fabric policies. Engineers need to map RoCEv2 traffic to dedicated lossless classes, enabling PFC on specific priorities only to prevent head‑of‑line blocking. ECN must be configured end‑to‑end, including switch marking thresholds and host congestion response, to avoid excessive pause storms. QoS policies should separate storage, management, and GPU traffic with appropriate scheduling and buffering. Standardized templates, rigorous testing with synthetic GPU traffic, and telemetry for PFC/ECN events are crucial to validate the configuration before onboarding production AI and HPC workloads.

    Get PFC & ECN Design Help

Lossless Ethernet for AI & HPC Switching

Build RoCEv2 lossless Ethernet fabrics with low-latency data center switches, PFC/ECN, and GPU‑ready connectivity for AI and HPC

High-Density 25/100G Fabric

Scale leaf–spine clusters with 25G to 100G ports for GPU and storage traffic growth

Deterministic Low Latency

RoCEv2‑optimized forwarding with microsecond latency for AI training and HPC jobs

Lossless PFC/ECN Intelligence

Switches with PFC, ECN, and advanced QoS to eliminate packet loss under congestion

Lossless Ethernet vs InfiniBand for AI & HPC Fabrics

Compare RoCEv2 lossless Ethernet and InfiniBand to choose the optimal low-latency network fabric for AI training, inference, and GPU-accelerated HPC clusters.

AspectInfiniBand Fabrics
Lossless Ethernet (RoCEv2)
Outcome for You
Latency & JitterUltra‑low latency with very tight jitter, but needs dedicated IB fabricMicrosecond‑level latency with deterministic behavior using PFC/ECNPredictable GPU job completion times without maintaining a separate IB network
Throughput & ScalabilityHigh throughput but large clusters may require complex multi‑rail designsScales leaf–spine to tens of thousands of GPUs on 25/100G EthernetGrow AI/HPC clusters using familiar DC Ethernet topologies and tools
Ecosystem & Vendor ChoiceTightly coupled to a few vendors, with limited switch and NIC diversityBroad ecosystem across Cisco, HPE Aruba, Juniper, Huawei and major NICsAvoid lock‑in, negotiate better pricing, and mix best‑of‑breed platforms
Operational ComplexitySeparate IB fabric, tools, and skills from your Ethernet data centerUnified operations using existing Ethernet monitoring, automation, and skillsLower OpEx and faster troubleshooting with one converged network stack
Cost & Investment ProtectionSpecialized hardware and cables can drive higher TCO and upgrade costsLeverages standard DC switches, optics, DAC/AOC and cablingReduce CapEx while reusing optics and cabling across AI and general workloads
Workload FlexibilityOptimized for tightly coupled HPC; less suited for mixed enterprise trafficSupports AI training, inference, storage, and tenant traffic on one fabricRun multi‑tenant cloud, storage, and GPU clusters over the same lossless Ethernet
Future ReadinessUpgrade paths depend on IB roadmap and may lag mainstream EthernetFollows rapid Ethernet speed evolution and open RoCEv2 standardsStay aligned with 100G+ roadmaps while keeping fabrics standards‑based

Need Help? Technical Experts Available Now.

  • +1-626-655-0998 (USA)
    UTC 15:00-00:00
  • +852-2592-5389 (HK)
    UTC 00:00-09:00
  • +852-2592-5411 (HK)
    UTC 06:00-15:00
Need Help? Technical Experts Available Now.

Lossless Ethernet Ideal Use Cases

Where RoCEv2‑ready, lossless Ethernet fabrics from Cisco, Aruba, Juniper, Fortinet, and Huawei unlock maximum GPU utilization, predictable latency, and scalable AI/HPC performance:

AI Training Clusters

AI Training Clusters

  • RoCEv2‑based, lossless Ethernet fabrics built on Cisco Nexus, Aruba CX, Juniper QFX/EX, and Huawei CloudEngine switches interconnect large‑scale GPU clusters for foundation models and LLM training. High‑density 25/100G ports, low‑latency forwarding, and PFC/ECN avoid congestion loss and deliver deterministic job completion for multi‑rack AI pods.
填写大场景标题.webp

Real-Time Inference

  • Leaf–spine fabrics using 10/25/100G lossless Ethernet switches and low‑latency DAC/AOC links provide predictable microsecond‑level delay for online inference, personalization, search, and recommendation engines. QoS, PFC, and ECN protect latency‑sensitive GPU traffic from noisy neighbors, ensuring stable SLAs across multi‑tenant AI services and edge gateways.
HPC Simulations

HPC Simulations

  • GPU‑accelerated HPC clusters for CFD, seismic processing, genomics, and risk analytics leverage RoCEv2‑optimized Ethernet to replace or complement InfiniBand. High‑throughput 40/100G links, cut‑through forwarding, and carefully tuned PFC/ECN reduce congestion‑induced jitter while compatible optics and cables keep interconnect latency and cost under control at scale.
Managed AI Clouds

Managed AI Clouds

  • MSPs and cloud providers deploy multi‑tenant lossless Ethernet fabrics to host AI and GPU HPC services for enterprise customers. Vendor‑validated optics, DAC/AOC, and OOB management switches simplify lifecycle operations, while advanced QoS and telemetry keep RoCEv2 traffic performant across shared leaf–spine domains and hybrid, inter‑DC AI architectures.

أسئلة مكررة

What is a lossless Ethernet fabric for AI & HPC, and why do I need RoCEv2, PFC, and ECN?

A lossless Ethernet fabric is a data center network designed to prevent packet drops under congestion, which is critical for GPU clusters, AI training, inference, and HPC workloads. Using RoCEv2 (RDMA over Converged Ethernet v2) over switches that support Priority Flow Control (PFC) and Explicit Congestion Notification (ECN) allows RDMA traffic to bypass the TCP/IP stack, delivering deterministic low latency and high throughput similar to InfiniBand while running on standard Ethernet switches, optics, and cables from vendors such as Cisco Nexus, HPE Aruba CX, Juniper QFX/EX, and Huawei CloudEngine.

How do I choose between RoCEv2-based lossless Ethernet and InfiniBand for my AI or GPU cluster?

  • Evaluate performance vs. ecosystem: InfiniBand may offer slightly lower latency at small scale, while RoCEv2 on lossless Ethernet provides excellent latency/throughput with broader vendor choice (Cisco, Aruba, Juniper, Huawei) and easier integration with existing data center networks.
  • Consider scalability and operations: RoCEv2 leaf–spine Ethernet fabrics scale seamlessly with familiar tooling, monitoring, and automation, enabling you to consolidate AI, storage, and general workloads on one converged network instead of running a separate InfiniBand fabric.

Are my existing optics and DAC/AOC cables compatible with your lossless Ethernet for AI & HPC solution?

Compatibility depends on switch platform, port speed, and transceiver/cable coding, but in most cases we can provide standards-based 10G/25G/40G/100G optical modules and DAC/AOC cables that are fully interoperable with Cisco Nexus, HPE Aruba, Juniper QFX/EX, and Huawei CloudEngine switches in RoCEv2 environments.
    Key compatibility considerations
  • Match form factor and speed: Ensure QSFP+/QSFP28/SFP+/SFP28 modules and DAC/AOC cables are rated for the target speeds (10/25/40/100G) and distances used in your GPU racks and spine connections.
  • Check vendor coding and interoperability: Use optics and cables coded for your target platforms or verified as multi-vendor compatible to avoid link issues or warning messages on Cisco, Aruba, Juniper, and Huawei switches.
    How router-switch.com can help
  • We provide pre-validated optical transceivers and low-latency DAC/AOC cable options for common AI and HPC topologies (leaf–spine, super-spine, and GPU pod designs), reducing risk during deployment.
  • Share your switch models, planned topology, and cable distances, and our team can recommend a fully compatible bill of materials (BOM) for optical modules, DAC/AOC, and management switches to support lossless RoCEv2 fabrics.

Which switch features are critical for building a stable RoCEv2 lossless Ethernet fabric for AI training?

For AI training clusters using RoCEv2, critical switch capabilities include hardware support for Priority Flow Control (PFC), Explicit Congestion Notification (ECN), Data Center Bridging (DCB), deep buffers, low-latency cut-through or smart buffering architectures, and rich QoS profiles to isolate RDMA traffic classes. Platforms such as Cisco Nexus, Aruba CX, Juniper QFX/EX, and Huawei CloudEngine combine these features with high-density 25G/100G ports and automation APIs, enabling you to build scalable, deterministic leaf–spine fabrics for GPU-accelerated workloads.

Can I mix vendors (Cisco, Aruba, Juniper, Huawei) in the same lossless AI & HPC Ethernet fabric?

Yes, many customers deploy multi-vendor RoCEv2 fabrics, provided that PFC/ECN behavior, QoS policies, and buffer configurations are carefully aligned across all switches. RoCEv2 is based on standard Ethernet and IP, so interoperation is feasible; however, each vendor may implement congestion control tuning and DCB features differently. Router-switch.com can help you select interoperable switch models, optics, and cables and provide best-practice configuration guidance for consistent lossless behavior across Cisco Nexus, Aruba CX, Juniper QFX/EX, and Huawei CloudEngine devices.

What kind of warranty and technical support can I expect for switches, optics, and cables in this AI & HPC solution?

Warranty and support options depend on the specific products and brands you choose (e.g., Cisco, HPE Aruba, Juniper, Fortinet, Huawei) as well as your region. Typically, customers combine the original vendor’s hardware warranty with optional service contracts and router-switch.com value-added services such as solution design assistance and lifecycle planning. Please note: Specific warranty terms and support services may vary by product and region. For accurate details, please refer to the official information. For further inquiries, please contact: router-switch.com.

Featured Reviews

Daniel Reynolds

We needed a predictable, lossless fabric for large-scale GPU training without blowing up our budget. Router-switch.com helped us design a RoCEv2-ready leaf–spine with Nexus and QFX plus matching optics and DACs. Performance and latency are rock solid, and their sourcing reliability and fast logistics made our rollout much smoother than expected.

Emily Tan

Our AI and storage teams were struggling with congestion and microbursts across mixed workloads. Router-switch.com proposed a lossless Ethernet stack with Aruba CX and Huawei CloudEngine plus certified 25G/100G optics. The result: stable PFC/ECN behavior, easier capacity planning, and excellent pre- and post-sales engineering support.

Omar Al Mansouri

As an MSP building shared AI clusters, we needed deterministic latency, multivendor switch options, and strict cost control. Router-switch.com delivered a complete solution—Cisco, Juniper, and Huawei switches, optics, and DACs—fully validated for RoCEv2. Their design guidance and lifecycle pricing transparency are now a core part of our planning.

المزيد من الحلول

Ethernet vs InfiniBand for AI & HPC Networks

Ethernet vs InfiniBand for AI & HPC Networks

A focused comparison of Ethernet and InfiniBand for AI/HPC fabrics—latency, scaling, RDMA, and cost trade-offs.

AI & HPC Networking
Copper vs Fiber vs DAC/AOC Interconnects Guide

Copper vs Fiber vs DAC/AOC Interconnects Guide

A complete comparison of copper, fiber, DAC, and AOC—latency, reach, cost, and 10G/25G/100G/400G deployment suitability.

Cabling & Transceivers
Beyond Banddelse: The 100G+ Data Center Architecture

Beyond Banddelse: The 100G+ Data Center Architecture

يجب أن يكون لديها مؤسسة 100G -النمو جاهزة AI، أداء الكمون صفر

مركز البيانات