Cisco Catalyst 3560-E Series is (Figure 1) an enterprise-class line of standalone access and aggregation switches that facilitate the deployment of secure converged applications while maximizing investment protection for evolving network and application requirements. Combining 10/100/1000 and Power over Ethernet (PoE) configurations with 10 Gigabit Ethernet uplinks, the Cisco Catalyst 3560-E Series access switches enhance worker productivity by enabling applications such as IP telephony, wireless, and video. Cisco Catalyst 3560-E Series aggregation switches deliver secure nonstop unified network services and versatile connectivity in a one rack-unit (1-RU) form factor for space and power constrained environments, enabling businesses to reduce total cost of ownership while maximizing investment protection.
Cisco Catalyst 3560-E Series Primary Features
• Cisco TwinGig converter module for migrating uplinks from Gigabit Ethernet to 10 Gigabit Ethernet
• Cisco EnergyWise for greenhouse gas emissions and operational cost optimization by measuring, reporting, and reducing energy consumption across the entire corporate infrastructure, well beyond the scope of IT.
• PoE configurations with 15.4W of PoE on all 48 ports
• Enhanced PoE supporting up to 20W of PoE per port
• Industry first portfolio to scale beyond 15.4W per port delivering maximum solution simplicity for 802.11n access point deployments
• Access switch models have modular fan and power supply with externally available backup
• Dual redundant modular power supplies and fans for Cisco Catalyst 3560E-12D and Catalyst 3560E-12SD aggregation switches for nonstop operation
• Multicast routing, IPv6 routing, and access control list (ACL) in hardware
• Out-of-band Ethernet management port along with RS-232 console port
Figure 1. Cisco Catalyst 3560-E Series Access and Aggregation Switches

Switch Configurations
Table 1. Switch Configurations.
|
Feature |
Description |
|
Cisco Catalyst 3560E-24TD |
24 Ethernet 10/100/1000 ports and 2 X2 10 Gigabit Ethernet uplinks |
|
Cisco Catalyst 3560E-24PD |
24 Ethernet 10/100/1000 ports with PoE and 2 X2 10 Gigabit Ethernet uplinks |
|
Cisco Catalyst 3560E-48TD |
48 Ethernet 10/100/1000 ports and 2 X2 10 Gigabit Ethernet uplinks |
|
Cisco Catalyst 3560E-48PD |
48 Ethernet 10/100/1000 ports with PoE and 2 X2 10 Gigabit Ethernet uplinks |
|
Cisco Catalyst 3560E-48PD-F |
48 Ethernet 10/100/1000 ports with 15.4W PoE on all 48 ports and 2 X2 10 Gigabit Ethernet uplinks |
|
Cisco Catalyst 3560E-12D |
12 X2 10 Gigabit Ethernet ports |
|
Cisco Catalyst 3560E-12SD |
12 SFP Gigabit Ethernet ports and 2 X2 10 Gigabit Ethernet ports |
Cisco Catalyst 3560-E Series Fixed Configuration Aggregation Switches
Figure 2. Cisco Catalyst 3560E-12D and Cisco Catalyst 3560E-12SD Switch (Back)

Cisco Catalyst 3560-E Software
Cisco EnergyWise Technology
10 Gigabit Ethernet Uplinks and the Cisco TwinGig Small Form-Factor Pluggable Converter
Figure 3. Cisco TwinGig Adapter Converting 10 Gigabit Ethernet X2 Interface into Two Gigabit Ethernet SFP Interfaces

Modular Power Supplies
• C3K-PWR-1150WAC: 1150WAC power supply with 800W PoE
• C3K-PWR-750WAC: 750WAC power supply for 24-port switch with 420W PoE
• C3K-PWR-265WAC: 265WAC power supply for 48- or 24-port switch without PoE
• C3K-PWR-265WDC: 265WDC power supply for 48- or 24-port switch without PoE
• C3K-PWR-300WAC: Cisco Catalyst 3560E-12D and 3560E-12SD 300WAC power supply
• C3K-PWR-300WDC: Cisco Catalyst 3560E-12D and 3560E-12SD 300WDC power supply
Power over Ethernet
Redundant Power System
Primary Features and Benefits
Ease of Use: Deployment
• Dynamic Host Configuration Protocol (DHCP) autoconfiguration of multiple switches through a boot server eases switch deployment.
• Automatic QoS (AutoQoS) simplifies QoS configuration in voice-over-IP (VoIP) networks by issuing interface and global switch commands to detect Cisco IP phones, classify traffic, and help enable egress queue configuration.
• Autonegotiation on all ports automatically selects half- or full-duplex transmission mode to optimize bandwidth.
• Dynamic Trunking Protocol (DTP) facilitates dynamic trunk configuration across all switch ports.
• Port Aggregation Protocol (PAgP) automates the creation of Cisco Fast EtherChannel® groups or Gigabit EtherChannel groups to link to another switch, router, or server.
• Link Aggregation Control Protocol (LACP) allows the creation of Ethernet channeling with devices that conform to IEEE 802.3ad. This feature is similar to Cisco EtherChannel technology and PAgP.
• Automatic media-dependent interface crossover (MDIX) automatically adjusts transmit and receive pairs if an incorrect cable type (crossover or straight-through) is installed.
• Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD allow unidirectional links caused by incorrect fiber-optic wiring or port faults to be detected and disabled on fiber-optic interfaces.
Availability and Scalability
• Flexlink provides link redundancy with convergence time less than 100ms without Spanning Tree Protocol. A pair of interfaces configured as primary and backup links can load balance traffic based on VLAN. IEEE 802.1s/w Rapid Spanning Tree Protocol (RSTP) and Multiple Spanning Tree Protocol (MSTP) provide rapid spanning-tree convergence independent of spanning-tree timers and also offer the benefit of Layer 2 load balancing and distributed processing.
• Per-VLAN Rapid Spanning Tree (PVRST+) allows rapid spanning-tree reconvergence on a per-VLAN spanning-tree basis, without requiring the implementation of spanning-tree instances.
• Cisco Hot Standby Router Protocol (HSRP) is supported to create redundant, failsafe routing topologies.
• Switch-port Autorecovery (Errdisable) automatically attempts to reactivate a link that is disabled because of a network error.
High-Performance IP Routing
• Basic IP unicast routing protocols (Static, Routing Information Protocol Version 1 [RIPv1], and RIPv2, RIPng, EIGRP stub) are supported for small-network routing applications.
• Advanced IP unicast routing protocols (OSPF, EIGRP, and BGPv4) are supported for load balancing and constructing scalable LANs. IPv6 routing (OSPFv3 and EIGRPv6) is supported in hardware for maximum performance. The IP Services feature set is required.
• Equal-cost routing facilitates Layer 3 load balancing and redundancy.
• Policy-based routing (PBR) allows superior control by facilitating flow redirection regardless of the routing protocol configured. The IP Services feature set is required.
• HSRP provides dynamic load balancing and failover for routed links, up to 32 unique HSRP links supported per unit. The group number can be reused for each VLAN configured in the switch.
• Protocol Independent Multicast (PIM) for IP multicast routing is supported, including PIM sparse mode (PIM-SM), Source Specific Multicast (SSM), PIM dense mode (PIM-DM), PIM sparse-dense mode and Source Specific Multicast (SSM). The IP Services feature set is required.
• Web Control Caching Protocol (WCCPv2) enables Wide Area Acceleration Services (WAAS), resulting in improved application response time and conservation of WAN bandwidth.
• Fallback bridging forwards non-IP traffic between two or more VLANs. The IP Services feature set is required.
Superior Quality of Service
• 802.1p class of service (CoS) and differentiated services code point (DSCP) field classification is provided, using marking and reclassification on a per-packet basis by source and destination IP address, MAC address, or Layer 4 TCP/UDP port number.
• Cisco control-plane and data-plane QoS ACLs on all ports help ensure proper marking on a per-packet basis.
• Eight egress queues per port help enable differentiated management of different traffic types across the switch. Four queues are user configurable and four are reserved for system use.
• Shaped Round Robin (SRR) scheduling helps ensure differential prioritization of packet flows by intelligently servicing the ingress queues and egress queues.
• Weighted Tail Drop (WTD) provides congestion avoidance at the ingress and egress queues before a disruption occurs.
• Strict priority queuing helps ensure that the highest-priority packets are serviced ahead of all other traffic.
• The Cisco committed information rate (CIR) function provides bandwidth in increments as low as 8 Kbps.
• Rate limiting is provided based on source and destination IP address, source and destination MAC address, Layer 4 TCP/UDP information, or any combination of these fields, using QoS ACLs (IP ACLs or MAC ACLs), class maps, and policy maps.
• Up to 64 aggregate or individual policers are available per Fast Ethernet or Gigabit Ethernet port.
Advanced Security
• DHCP Snooping prevents malicious users from spoofing a DHCP server and sending out invalid addresses. This feature is used by other primary security features to prevent a number of other attacks such as ARP poisoning.
• Dynamic ARP Inspection (DAI) helps ensure user integrity by preventing malicious users from exploiting the insecure nature of the ARP protocol.
• IP source guard prevents a malicious user from spoofing or taking over another user's IP address by creating a binding table between the client's IP and MAC address, port, and VLAN.
• Private VLANs restrict traffic between hosts in a common segment by segregating traffic at Layer 2, turning a broadcast segment into a nonbroadcast multi-access-like segment.
• Private VLAN Edge provides security and isolation between switch ports, which helps ensure that users cannot snoop on other users' traffic.
• Unicast RPF feature helps mitigate problems caused by the introduction of malformed or forged (spoofed) IP source addresses into a network by discarding IP packets that lack a verifiable IP source address.
• IEEE 802.1x allows dynamic, port-based security, providing user authentication.
• IEEE 802.1x with VLAN assignment allows a dynamic VLAN assignment for a specific user regardless of where the user is connected.
• IEEE 802.1x with voice VLAN permits an IP phone to access the voice VLAN irrespective of the authorized or unauthorized state of the port.
• IEEE 802.1x and port security are provided to authenticate the port and manage network access for all MAC addresses, including that of the client.
• IEEE 802.1x with an ACL assignment allows for specific identity-based security policies regardless of where the user is connected.
• IEEE 802.1x with guest VLAN allows guests without 802.1x clients to have limited network access on the guest VLAN.
• Web authentication for non-802.1x clients allows non-802.1x clients to use an SSL-based browser for authentication.
• Multi-Domain Authentication allows an IP phone and a PC to authenticate on the same switch port while placing them on appropriate voice and data VLANs.
• MAC Auth Bypass (MAB) for voice allows third-party IP phones without an 802.1x supplicant to get authenticated using their MAC address.
• Cisco security VLAN ACLs on all VLANs prevent unauthorized data flows from being bridged within VLANs.
• Cisco standard and extended IP security router ACLs define security policies on routed interfaces for control-plane and data-plane traffic. IPv6 ACLs can be applied to filter IPv6 traffic.
• Port-based ACLs for Layer 2 interfaces allow security policies to be applied on individual switch ports.
• Secure Shell (SSH) Protocol, Kerberos, and Simple Network Management Protocol Version 3 (SNMPv3) provide network security by encrypting administrator traffic during Telnet and SNMP sessions. SSH Protocol, Kerberos, and the cryptographic version of SNMPv3 require a special cryptographic software image because of U.S. export restrictions.
• Bidirectional data support on the Switched Port Analyzer (SPAN) port allows the Cisco intrusion detection system (IDS) to take action when an intruder is detected.
• TACACS+ and RADIUS authentication facilitates centralized control of the switch and restricts unauthorized users from altering the configuration.
• MAC Address Notification allows administrators to be notified of users added to or removed from the network.
• Port Security secures the access to an access or trunk port based on MAC address.
• Multilevel security on console access prevents unauthorized users from altering the switch configuration.
• Bridge protocol data unit (BPDU) guard shuts down Spanning Tree PortFast-enabled interfaces when BPDUs are received to avoid accidental topology loops.
• Spanning Tree Root Guard (STRG) prevents edge devices not in the network administrator's control from becoming Spanning Tree Protocol root nodes.
• IGMP filtering provides multicast authentication by filtering out nonsubscribers and limits the number of concurrent multicast streams available per port.
• Dynamic VLAN assignment is supported through implementation of VLAN Membership Policy Server client capability to provide flexibility in assigning ports to VLANs. Dynamic VLAN facilitates the fast assignment of IP addresses.
Intelligent Power over Ethernet (PoE) Management
• Cisco Discovery Protocol version 2 allows the Cisco Catalyst 3560-E Series Switch to negotiate a more granular power setting when connecting to a Cisco powered device, such as IP phones or access points, than what is provided by IEEE classification.
• Per Port power consumption command allows customer to specify maximum power setting on an individual port.
• Per Port PoE Power Sensing measures actual power being drawn, enabling more intelligent control of powered devices.
• The PoE MIB provides proactive visibility into power usage and allows customers to set different power level thresholds
• Link Layer Discovery Protocol (LLDP and LLDP-MED) adds support for IEEE 802.1AB link layer discovery protocol for interoperability in multivendor networks. Switches exchange speed, duplex, and power settings with end devices such as IP phones.
Management and Control Features
• Cisco IOS Software CLI support provides common user interface and command set with all Cisco routers and Cisco Catalyst desktop switches.
• Generic On-Line Diagnostics (GOLD) checks the health of hardware components and verifies proper operation of the system data and control plane at run time and boot time.
• Virtual Route Forwarding (VRF)-Lite enables a service provider to support two or more VPNs with overlapping IP addresses.
• Switching Database Manager Templates for access, routing, and VLAN deployment allow the administrator to easily maximize memory allocation to the desired features based on deployment-specific requirements.
• With Cisco IOS Software IP SLAs, users can verify service guarantees, increase network reliability by validating network performance, proactively identify network issues, and increase return on investment (ROI) by easing the deployment of new IP services.
• Local Proxy Address Resolution Protocol (ARP) works in conjunction with Private VLAN Edge to minimize broadcasts and maximize available bandwidth.
• VLAN1 minimization allows VLAN1 to be disabled on any individual VLAN trunk.
• Internet Group Management Protocol (IGMP) Snooping for IPv4 and IPv6 MLD v1 and v2 Snooping provide fast client joins and leaves of multicast streams and limit bandwidth-intensive video traffic to only the requestors.
• Multicast VLAN Registration (MVR) continuously sends multicast streams in a multicast VLAN while isolating the streams from subscriber VLANs for bandwidth and security reasons.
• Per-port broadcast, multicast, and unicast storm control prevents faulty end stations from degrading overall systems performance.
• Voice VLAN simplifies telephony installations by keeping voice traffic on a separate VLAN for easier administration and troubleshooting.
• Cisco VLAN Trunking Protocol (VTP) supports dynamic VLANs and dynamic trunk configuration across all switches.
• Remote Switch Port Analyzer (RSPAN) allows administrators to remotely monitor ports in a Layer 2 switch network from any other switch in the same network.
• For enhanced traffic management, monitoring, and analysis, the Embedded Remote Monitoring (RMON) software agent supports four RMON groups (history, statistics, alarms, and events).
• Layer 2 traceroute eases troubleshooting by identifying the physical path that a packet takes from source to destination.
• Trivial File Transfer Protocol (TFTP) reduces the cost of administering software upgrades by downloading from a centralized location.
• Network Timing Protocol (NTP) provides an accurate and consistent timestamp to all intranet switches.
• Multifunction LEDs per port for port status; half-duplex and full-duplex mode; and 10BASE-T, 100BASE-TX, and 1000BASE-T indication as well as switch-level status LEDs for system, redundant-power supply, and bandwidth utilization provide a comprehensive and convenient visual management system.
• Jumbo frames (9216 bytes) are available on the 10/100/1000 configurations for advanced data and video applications requiring very large frames.
Network Management Tools
Cisco Network Assistant
• Configuration management
• Troubleshooting advice
• Inventory reports
• Event notification
• Network security settings
• Password synchronization
• Drag-and-drop Cisco IOS Software upgrades
• Secure wireless
CiscoWorks LAN Management Solution (LMS)
• Network discovery, topology views, end-station tracking, and VLAN management
• Real-time network fault analysis with easy-to-deploy device-specific best-practice templates
• Hardware and software inventory management, centralized configuration tools, and Syslog monitoring
• Network response time and availability monitoring and tracking
• Real-time device, link, and port traffic management, analysis, and reporting
Cisco Catalyst 3560 SFP Interconnect Cable
Figure 4. Cisco Catalyst 3560 SFP Interconnect Cable

Product Specifications
Table 2. Descriptions and Specifications
|
Description |
Specification |
||||||||
|
Performance |
Switching Fabric |
128 Gbps |
|||||||
|
DRAM |
128 MB / 256 MB * |
||||||||
|
FLASH |
64 MB |
||||||||
|
VLANs |
1K |
||||||||
|
VLAN IDs |
4K |
||||||||
|
Switched Virtual Interfaces (SVIs) |
1K |
||||||||
|
Jumbo Frames |
9216 Byte |
||||||||
|
Forwarding rate: |
|||||||||
|
3560E-24TD |
65.5 Mpps |
||||||||
|
3560E-24PD |
65.5 Mpps |
||||||||
|
3560E-48TD |
101.2 Mpps |
||||||||
|
3560E-48PD |
101.2 Mpps |
||||||||
|
3560E-48PD-F |
101.2 Mpps |
||||||||
|
3560E-12D |
90 Mpps |
||||||||
|
3560E-12SD |
47.6 Mpps |
||||||||
|
MAC, routing, security, and QoS scalability numbers depend on the type of template used in the switch: |
|||||||||
|
Default Template |
Default Template |
Access Template |
VLAN Template |
Routing Template |
|||||
|
MAC address |
6K |
4K |
12K |
3K |
|||||
|
IGMP groups and multicast routes |
1K |
1K |
1K |
1K |
|||||
|
Total unicast routes |
8K |
6K |
0 |
11K |
|||||
|
Directly connected hosts |
6K |
4K |
0 |
3K |
|||||
|
Indirect routes |
2K |
2K |
0 |
8K |
|||||
|
Security ACEs |
1K |
2K |
1K |
1K |
|||||
|
QoS ACEs |
0.5K |
0.5K |
0.5K |
0.5K |
|||||
|
PBR ACEs |
0 |
0.5K |
0 |
0.5K |
|||||
|
Connectors and Cabling |
• 1000BASE-T ports: RJ-45 connectors, 2-pair Cat-5 UTP cabling
• 1000BASE-T SFP-based ports: RJ-45 connectors, 2-pair Cat-5 UTP cabling
• 100BASE-FX, 1000BASE-SX, -LX/LH, -ZX, -BX10 and CWDM SFP-based ports: LC fiber connectors (single-mode, or multimode fiber)
• 10GBASE-SR, LR, ER, CX4, LX4, LRM X2-based ports: SC fiber connectors (single-mode, or multimode fiber)
• Ethernet management port: RJ-45 connectors, 2-pair Cat-5 UTP cabling
• Management console port: RJ-45-to-DB9 cable for PC connections
|
||||||||
|
Power Connectors |
• Customers can provide power to an access switch by using either the internal power supply or the Cisco RPS 2300. The connectors are located at the back of the switch.
• The Cisco Catalyst 3560E-12D and Catalyst 3560E-12SD have dual power supplies and do not support the RPS.
• Internal power supply connector: The internal power supply is an autoranging unit. The internal power supply supports input voltages between 100 and 240VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
• Cisco RPS connector: The connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.
• Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-supply receptacle.
|
||||||||
|
Indicators |
• Per-port status LEDs: link integrity, disabled, activity, speed, and full-duplex indications
• System-status LEDs: system, RPS, and bandwidth-utilization indications (on the Cisco Catalyst 3560E-12D and 3560E-12SD only: system, power supplies, fans)
|
||||||||
|
Dimensions (H x W x D) |
Inches |
Centimeters |
|||||||
|
3560E-24TD |
1.75 x 17.5 x 17.4 |
4.45 x 44.5 x 44.19 |
|||||||
|
3560E-24PD |
1.75 x 17.5 x 17.4 |
4.45 x 44.5 x 44.19 |
|||||||
|
3560E-48TD |
1.75 x 17.5 x 17.4 |
4.45 x 44.5 x 44.19 |
|||||||
|
3560E-48PD |
1.75 x 17.5 x 17.4 |
4.45 x 44.5 x 44.19 |
|||||||
|
3560E-48PD-F |
1.75 x 17.5 x 21.7 |
4.45 x 44.5 x 55.2 |
|||||||
|
3560E-12D |
1.75 x 17.5 x 19.5 |
4.45 x 44.5 x 49.5 |
|||||||
|
3560E-12SD |
1.75 x 17.5 x 15 |
4.45 x 44.5 x 38.1 |
|||||||
|
Weight |
Pounds |
Kilograms |
|||||||
|
3560E-24TD |
17.9 |
8.1 |
|||||||
|
3560E-24PD |
18.3 |
8.3 |
|||||||
|
3560E-48TD |
18.8 |
8.6 |
|||||||
|
3560E-48PD |
19.2 |
8.75 |
|||||||
|
3560E-48PD-F |
20.9 |
9.5 |
|||||||
|
3560E-12D |
23.5 |
10.7 |
|||||||
|
3560E-12SD |
16 |
7.27 |
|||||||
|
Environmental Ranges |
• Operating temperature: 32 to 113ºF (0 to 45ºC)
• Storage temperature: -13 to 158ºF (-25 to 70ºC)
• Relative humidity operating: 0 to 95% (noncondensing)
• Relative humidity nonoperating: 10 to 85% (noncondensing)
• Operating altitude: up to 10,000 ft (3049 m)
• Storage altitude: up to 15,000 ft (4573 m)
• Cisco Catalyst 3560E-12D and Catalyst 3560E-12SD: up to 50,000 feet over allowable temperature range; NEBS - up to 13,000 feet [4000 m]
|
||||||||
|
Acoustic Noise |
International Organization for Standardization (ISO) 7779: bystander position operating to an ambient temperature of 30ºC |
||||||||
|
3560E-24TD |
45 dB |
||||||||
|
3560E-48TD |
45 dB |
||||||||
|
3560E-24PD |
45 dB |
||||||||
|
3560E-48PD |
45 dB |
||||||||
|
3560E-48PD-F |
48 dB |
||||||||
|
3560E-12D |
44 dB |
||||||||
|
3560E-12SD |
44 dB |
||||||||
|
Mean Time Between Failure (MTBF) |
3560E-24TD |
181,086 hours |
|||||||
|
3560E-24PD |
168,753 hours |
||||||||
|
3560E-48TD |
166,907 hours |
||||||||
|
3560E-48PD |
151,196 hours |
||||||||
|
3560E-48PD-F |
151,196 hours |
||||||||
|
3560E-12D |
147,001 hours |
||||||||
|
3560E-12SD |
206,950 hours |
||||||||
Table 3. Management and Standards Support for Cisco Catalyst 3560-E Series Switches
|
Description |
Specification |
|
|
Management |
• BRIDGE-MIB
• CISCO-CDP-MIB
• CISCO-CLUSTER-MIB
• CISCO-CONFIG-MAN-MIB
• CISCO-ENTITY-FRU-CONTROL-MIB
• CISCO-ENVMON-MIB
• CISCO-FLASH-MIB
• CISCO-FTP-CLIENT-MIB
• CISCO-HSRP-MIB
• CISCO-HSRP-EXT-MIB
• CISCO-IGMP-FILTER-MIB
• CISCO-IMAGE-MIB
• CISCO-IP-STAT-MIB
• CISCO-L2L3-INTERFACE-CONFIG-MIB
• CISCO-POE-EXTENSIONS-MIB
• CISCO-MAC-NOTIFICATION-MIB
• CISCO-MEMORY-POOL-MIB
• CISCO-PAGP-MIB
• CISCO-PING-MIB
• CISCO-PROCESS-MIB
• CISCO-RTTMON-MIB
• CISCO-STP-EXTENSIONS-MIB
• CISCO-SYSLOG-MIB
• CISCO-TCP-MIB
• CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
• CISCO-VLAN-MEMBERSHIP-MIB
|
• CISCO-VTP-MIB
• ENTITY-MIB
• ETHERLIKE-MIB
• IF-MIB
• IGMP-MIB
• IPMROUTE-MIB
• OLD-CISCO-CHASSIS-MIB
• OLD-CISCO-FLASH-MIB
• OLD-CISCO-INTERFACES-MIB
• OLD-CISCO-IP-MIB
• OLD-CISCO-SYS-MIB
• OLD-CISCO-TCP-MIB
• OLD-CISCO-TS-MIB
• OSPF-MIB (RFC 1253)
• PIM-MIB
• RFC1213-MIB
• RFC1253-MIB
• RMON-MIB
• RMON2-MIB
• SNMP-FRAMEWORK-MIB
• SNMP-MPD-MIB
• SNMP-NOTIFICATION-MIB
• SNMP-TARGET-MIB
• SNMPv2-MIB
• TCP-MIB
• UDP-MIB
|
|
Standards |
• IEEE 802.1s
• IEEE 802.1w
• IEEE 802.1x
• IEEE 802.3ad
• IEEE 802.3af
• IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1p CoS Prioritization
• IEEE 802.1Q VLAN
• IEEE 802.3 10BASE-T specification
• IEEE 802.3u 100BASE-TX specification
• IEEE 802.3ab 1000BASE-T specification
• IEEE 802.3z 1000BASE-X specification
• 100BASE-FX
• 1000BASE-T
• 1000BASE-SX
|
• 1000BASE-LX/LH
• 1000BASE-BX10-U
• 1000BASE-BX10-D
• 1000BASE-ZX
• 1000BASE-CWDM SFP 1470 nm
• 1000BASE-CWDM SFP 1490 nm
• 1000BASE-CWDM SFP 1510 nm
• 1000BASE-CWDM SFP 1530 nm
• 1000BASE-CWDM SFP 1550 nm
• 1000BASE-CWDM SFP 1570 nm
• 1000BASE-CWDM SFP 1590 nm
• 1000BASE-CWDM SFP 1610 nm
• 10GBASE-SR
• 10GBASE-LR
• 10GBASE-ER
• RMON I and II standards
• SNMPv1, SNMPv2c, and SNMPv3
|
Table 4. Power Supply Compatibility Matrix
|
Cisco Catalyst 3560-E Series Switch Type |
Power Supply |
|||||
|
C3K-PWR-1150WAC |
C3K-PWR-750WAC |
C3K-PWR-265WAC |
C3K-PWR-265WDC |
C3K-PWR-300WAC |
C3K-PWR-300WDC |
|
|
48-Port PoE Switch |
X |
X |
- |
- |
- |
- |
|
24-Port PoE Switch |
X |
X |
- |
- |
- |
- |
|
48-Port Switch |
X |
X |
X |
X |
- |
- |
|
24-Port Switch |
X |
X |
X |
X |
- |
- |
|
Cisco RPS 2300 |
X |
X |
- |
- |
- |
- |
|
Cisco Catalyst |
- |
- |
- |
- |
X |
X |
|
Cisco Catalyst |
- |
- |
- |
- |
X |
X |
Table 5. Power Specifications
|
Description |
Specifications |
||||||
|
C3K-PWR-1150WAC |
C3K-PWR-750WAC |
C3K-PWR-265WAC |
C3K-PWR-265WDC |
C3K-PWR-300WAC |
C3K-PWR-300WDC |
||
|
Max Output Power |
1150W |
750W |
265W |
265W |
300W |
300W |
|
|
Total Output BTU (Note: 1000 BTU/hr=290W) |
3939 BTU/hr, 1150W |
2568 BTU/hr, 765W |
907 BTU/hr, 265W |
907 BTU/hr, 265W |
1034 BTU/hr, 300W |
||
|
Input-Voltage Range and Frequency |
115-240VAC, 50-60 Hz |
100-240VAC, 50-60 Hz |
100-240VAC, 50-60 Hz |
-36VDC to -72VDC |
85-265VAC, 47-63 Hz |
-40.5VDC to -72VDC |
|
|
Input Current |
12-6A |
10-5A |
5-2.5A |
<5A@-72VDC <10A@-36VDC |
4-2A |
8A |
|
|
Output Ratings |
12V@25A -52V@16.4A |
12V@25A -52V@8.75A |
12V@22A |
12V@22A |
12V@25A |
12V@25A |
|
|
Output Holdup Time |
20 ms minimum |
20 ms minimum |
20 ms minimum |
> 2ms@-48VDC |
20 ms minimum |
8ms |
|
|
Power-Supply Input Receptacles |
IEC 320-C14 (IEC60320-C14) |
IEC 320-C14 (IEC60320-C14) |
IEC 320-C14 (IEC60320-C14) |
- |
IEC 320-C14 (IEC60320-C14) |
- |
|
|
Power Cord Rating |
15A |
15A |
15A |
12A@-100VDC |
10A |
12AWG |
|
|
Description |
Specifications |
||||||
|
WS-C3560E-48PD-SF |
WS-C3560E-24PD-S |
WS-C3560E-48PD-S |
WS-C3560E-24TD-S |
WS-C3560E-48TD-S |
WS-C3560E-12SD |
WS-C3560E-12D |
|
|
C3K-PWR-1150WAC |
C3K-PWR-750WAC |
C3K-PWR-265WAC |
C3K-PWR-265WDC |
C3K-PWR-300WAC |
C3K-PWR-300WAC or C3K-PWR-265WDC |
C3K-PWR-300WAC or C3K-PWR-265WDC |
|
|
100% Throughput |
|||||||
|
Measured Power Consumption |
146W |
89W |
133W |
89W |
151W |
82W |
193W |
|
Measured Output BTU/hr |
498 |
303 |
451 |
303 |
514 |
279 |
657 |
|
5% Throughput |
|||||||
|
Measured Power Consumption |
137W |
94W |
124W |
96W |
141W |
80W |
189W |
|
Measured Output BTU/hr |
466 |
320 |
420 |
292 |
481 |
272 |
644 |
|
5% Throughput (with 50% PoE loads) |
|||||||
|
Measured Power Consumption |
Switch Power: 558W PoE Power: 385W |
Switch Power: 297W PoE Power: 193W |
Switch Power: 332W PoE Power: 196W |
N/A |
N/A |
N/A |
N/A |
|
Measured Output BTU/hr |
At the Switch: 590 |
At the Switch: 355 |
At the Switch: 464 |
N/A |
N/A |
N/A |
N/A |
|
100% Throughput (with maximum possible PoE loads) |
|||||||
|
Measured Power Consumption |
Switch Power: 972W PoE Power: 744W |
Switch Power: 502W PoE Power: 372W |
Switch Power: 540W PoE Power: 375W |
N/A |
N/A |
N/A |
N/A |
|
Measured Output BTU/hr |
At the Switch: 778 |
At the Switch: 443 |
At the Switch: 561 |
N/A |
N/A |
N/A |
N/A |
Note: Disclaimer: All power consumption numbers were measured under controlled laboratory conditions and are provided as an estimate.
Non-PoE Power Consumption
100 Percent Throughput Switch Power Consumption
5 Percent Throughput Switch Power Consumption
PoE Power Consumption
100 Percent Throughput Switch Power Consumption (no PoE loads)
Measured 5 Percent Throughput Switch Power Consumption (no PoE loads)
100 Percent Throughput Switch Power Consumption (with maximum PoE loads)
5 Percent Throughput Switch Power Consumption (with 50 percent PoE loads).
Table 6. Power Supply Specifications
|
Product Specifications |
Power Supply |
||||||
|
C3K-PWR-1150WAC |
C3K-PWR-750WAC |
C3K-PWR-265WAC |
C3K-PWR-265WDC |
C3K-PWR-300WAC |
C3K-PWR-300WDC |
||
|
Physical Specifications |
(H x W x D): 1.65 X 6.0 X 14.90 in Weight: 5.6 lb (2.6 kg) |
(H x W x D): 1.65 X 6.0 X 11.4 in Weight: 3.9 lb (1.8 kg) |
(H x W x D): 1.65 X 6.0 X 11.4 in Weight: 3.3 lb (1.5 kg) |
(H x W x D): 1.65 X 6.0 X 11.4 in Weight: 3.5 lb (1.6 kg) |
(H x W x D): 1.58 X 4.0 x 9.0 in Weight: (2 Kg) |
||
|
Operating Temperature |
23 to 113°F (-5 to 45°C) |
23 to 131°F (-5 to 55°C) |
|||||
|
Storage Temperature |
-40 to 158°F (-40 to 70°C) |
-40 to 185°F (-40 to 85°C) |
|||||
|
Relative Humidity Operating |
10 to 85% noncondensing |
10 to 90% noncondensing |
|||||
|
Relative Humidity Nonoperating |
0 to 95% noncondensing |
5 to 95% noncondensing |
|||||
|
Altitude |
10,000 ft. (3000 meters), up to 45°C |
Operating: -500 to 10,000 ft. Nonoperating: -1,000 to 50,000 ft. (-304 to 15,240 m) over allowable temperature range |
|||||
|
MTBF |
Calculated MTBF must be greater than 300,000 hrs using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hrs (with 90% confidence level). |
Calculated MTBF 220,000 hrs with fan (MIL HDBK 217F formula). Demonstrated MTBF 150,000 hrs with 90% confidence. |
Calculated MTBF 662,000 hrs with fan (Bellcore formula). Demonstrated MTBF 150,000 hrs with 90% confidence. |
||||
|
EMI and EMC Compliance |
• FCC Part 15 (CFR 47) Class A
• ICES-003 Class A
• EN 55022 Class A
• CISPR 22 Class A
• AS/NZS 3548 Class A
• VCCI Class A
• EN 55024
• EN300 386
• EN 50082-1
• EN 61000-3-2
• EN 61000-3-3
• EN 61000-6-1
• NEBS Compliant (Except C3K-PWR-1150WAC and C3K-PWR-750WAC)
|
||||||
|
Safety Compliance |
• UL 60950-1 1st Edition
• CAN/CSA-C22.2 No. 60950-1 1st Edition
• EN 60950-1 1st Edition
• IEC 60950-1 1st Edition
|
||||||
|
LED Indicators |
• "AC OK" or "DC IN": Input power to the power supply is OK.
• "PS OK": Output power from the power supply is OK.
|
• "AC OK": Input power to the power supply is OK.
• "PS OK": Output power from the power supply is OK.
|
|||||
Table 7. Safety and Compliance
|
Description |
Specification |
|
Safety Certifications |
• UL60950-1
• C-UL to CAN/CSA 22.2 No.60950-1
• TUV/GS to EN 60950-1
• CB to IEC 60950-1 with all country deviations
• CE Marking
• CCC for PS FRU
|
|
Electromagnetic Emissions Certifications |
• FCC Part 15 Class A
• EN 55022 Class A (CISPR22 Class A)
• CNS13438 Class A (applicable only to FRU power supplies)
• AS/NZS CISPR22 Class A
• EN55024
• GR-1089 CORE Class A
• EN 300 368
• MIC
• CE Marking
• China (applicable only to FRU power supplies)
|
|
NEBS |
• GR-63-CORE, GR-1089-CORE
• Level 3 Type 2, 4 and Wall Mount
• AT&T TP76200 Checklist
• TCG NEBS Checklist
|
|
ETSI |
EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use: Class 3.2 |
|
Environmental |
Reduction of Hazardous Substances (ROHS) 5 |
|
Noise Specifications |
Office Product Spec: 48dBA at 30°C (refer to ISO 7779) |
|
Telco |
CLEI code |
|
Warranty |
Limited lifetime warranty |
Hardware Warranty
Cisco Services for Access Switching
Ordering Information
Table 8. Cisco Catalyst 3560-E Series Ordering Info
|
Product Number |
Product Description |
|
Cisco Catalyst 3560-E Series |
|
|
• 24 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 265WAC power supply and fan tray
• 1 rack unit (RU) fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 24 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 265WAC power supply and fan tray
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
|
• 24 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 160-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable DC power supply and fan tray
• 1 rack unit (RU) multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 48 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 265WAC power supply and fan tray
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 48 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 160-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable DC power supply and fan tray
• 1 rack unit (RU) multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 48 10/100/1000 ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 265WAC power supply and fan tray
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
|
• 24 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 750WAC power supply and fan tray
• 420W available for Enhanced PoE, allowing > 15.4W to all 24 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 24 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 750WAC power supply and fan tray
• 420W available for Enhanced PoE, allowing > 15.4W to all 24 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
|
• 48 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 750WAC power supply and fan tray
• 420W available for Enhanced PoE allowing > 15.4W for up to 24 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 48 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 750WAC power supply and fan tray
• 420W available for Enhanced PoE allowing > 15.4W for up to 24 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
|
• 48 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 1150WAC power supply and fan tray
• 800W available for Enhanced PoE, allowing > 15.4W to all 48 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
|
• 48 10/100/1000 PoE ports + 2 X2-based 10 Gigabit Ethernet ports
• 128-Gbps wire rate, nonblocking switching fabric capacity
• Field-replaceable 1150WAC power supply and fan tray
• 800W available for Enhanced PoE, allowing > 15.4W to all 48 ports
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
|
WS-C3560E-12D-S |
• 12 X2-based 10 Gigabit Ethernet ports
• 60 Gbps, backplane utilization 2:1 oversubscribed
• Dual hot-swappable 300WAC or DC power supplies and redundant fans
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
WS-C3560E-12D-E |
• 12 X2-based 10 Gigabit Ethernet ports
• 60 Gbps, backplane utilization 2:1 oversubscribed
• Dual hot-swappable 300WAC or DC power supplies and redundant fans
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
WS-C3560E-12SD-S |
• 12 SFP based Gigabit Ethernet ports + 2 X2-based 10 Gigabit Ethernet ports
• 68 Gbps, wire rate backplane
• Dual hot-swappable 300WAC or DC power supplies and redundant field-replaceable fans
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Base software feature set (IPB)
|
|
WS-C3560E-12SD-E |
• 12 SFP based Gigabit Ethernet ports + 2 X2-based 10 Gigabit Ethernet ports
• 68 Gbps, wire rate backplane
• Dual hot-swappable 300WAC or DC power supplies and redundant field-replaceable fans
• 1-RU fixed configuration multilayer switch
• IPv6
• IP Services software feature set (IPS)
• Provides full IPv6 dynamic routing
|
|
Cisco Catalyst 3560-E Series Product Activation Keys |
|
|
3560E-LIC= |
|
|
Cisco Catalyst 3560-E Series Product Activation Keys Configurations |
|
|
3560E-IPSLCB-QTY |
IP Services for 3560-E, upgrade from the IP Base Feature Set |
|
3560E12D-SLB-QTY |
IP Services for 3560E-12D, upgrade from IP Base |
|
3560E12SD-SLB-QTY |
IP Services for 3560E-12SD, upgrade from IP Base |
|
Power Supplies and Fan Module for the Cisco Catalyst 3560-E Series |
|
|
C3K-PWR-265WAC= |
Catalyst 3750-E/3560-E 265WAC power supply |
|
C3K-PWR-265WDC= |
Catalyst 3750-E/3560-E 265WDC power supply |
|
C3K-PWR-750WAC= |
Catalyst 3750-E/3560-E/RPS 2300 750WAC power supply |
|
C3K-PWR-1150WAC= |
Catalyst 3750-E/3560-E/RPS 2300 1150WAC power supply |
|
C3K-BLWR-60CFM= |
Fan Module for the Catalyst 3750-E/3560-E |
|
Power Supplies and Fan Module for the Cisco Catalyst 3560E-12D and Catalyst 3560E-12SD Aggregation Switches |
|
|
C3K-PWR-300WAC= |
Catalyst 3560E-12D and Catalyst 3560E-12SD 300WAC power supply spare |
|
C3K-PWR-300WDC= |
Catalyst 3560E-12D and Catalyst 3560E-12SD 300WDC power supply spare |
|
C3K-FAN-16CFM= |
Fan Module for the Catalyst 3560E-12D and Catalyst 3560E-12SD |
|
Redundant Power System for the Cisco Catalyst 3560-E Series |
|
|
PWR-RPS2300 |
Cisco Redundant Power System 2300 and Blower,No Power Supply |
|
ACC-RPS2300= |
Spare Accessory Kit for Cisco Redundant Power System 2300 |
|
BLNK-RPS2300= |
Spare Bay Insert for Cisco Redundant Power System 2300 |
|
CAB-RPS2300= |
Spare RPS2300 Cable for Devices other than E-Series Switches |
|
CAB-RPS2300-E= |
Spare RPS2300 Cable for Catalyst 3750E/3560E Switches |
|
PWR-RPS2300= |
Spare RPS 2300 Chassis w/ Blower, PS blank, No Power Supply |
|
BLWR-RPS2300= |
Spare 45CFM Blower for Cisco Redundant Power System 2300 |
|
C3K-PWR-750WAC= |
Catalyst 3750-E/3560-E/RPS 2300 750WAC power supply spare |
|
C3K-PWR-1150WAC= |
Catalyst 3750-E/3560-E/RPS 2300 1150WAC power supply spare |
|
TwinGig Converter Module for the Cisco Catalyst 3560-E Series |
|
|
CVR-X2-SFP |
TwinGig Converter Module |
|
CVR-X2-SFP= |
TwinGig Converter Module |
|
SFPs for the Cisco Catalyst 3560-E Series |
|
|
GLC-GE-100FX= |
100BASE-FX SFP for GE SFP port on 3750,3560.2970,2960 |
|
GLC-LH-SM= |
GE SFP,LC connector LX/LH transceiver |
|
GLC-SX-MM= |
GE SFP, LC connector SX transceiver |
|
GLC-T= |
1000BASE-T SFP |
|
GLC-ZX-SM= |
1000BASE-ZX SFP |
|
GLC-BX-D= |
1000BASE-BX SFP, 1490NM |
|
GLC-BX-U= |
1000BASE-BX SFP, 1310NM |
|
CWDM-SFP-1470= |
CWDM 1470 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1490= |
CWDM 1490 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1510= |
CWDM 1510 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1530= |
CWDM 1530 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1550= |
CWDM 1550 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1570= |
CWDM 1570 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1590= |
CWDM 1590 NM SFP Gigabit Ethernet and 1G/2G FC |
|
CWDM-SFP-1610= |
CWDM 1610 NM SFP Gigabit Ethernet and 1G/2G FC |
|
DWDM SFPs for Cisco Catalyst 3560-E Series (not currently supported with the Cisco Catalyst 3560E-12D & Catalyst 3560E-12SD) |
|
|
DWDM-SFP-3033= |
DWDM SFP 1530.33 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3112= |
1000BASE-DWDM 1531.12 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3190= |
1000BASE-DWDM 1531.90 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3268= |
DWDM SFP 1532.68 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3425= |
DWDM SFP 1534.25 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3504= |
DWDM SFP 1535.04 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3582= |
DWDM SFP 1535.82 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3661= |
DWDM SFP 1536.61 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3819= |
DWDM SFP 1538.19 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3898= |
DWDM SFP 1538.98 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-3977= |
DWDM SFP 1539.77 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-4056= |
DWDM SFP 1540.56 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-4214= |
DWDM SFP 1542.14 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-4294= |
DWDM SFP 1542.94 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-4373= |
DWDM SFP 1543.73 nm SFP (100 GHz ITU grid) |
|
DWDM-SFP-4453= |
DWDM SFP 1544.53 nm SFP (100 GHz ITU grid) |
|
10GB X2 Module for Cisco Catalyst 3560-E Series |
|
|
X2-10GB-ER= |
10GBASE-ER X2 Module |
|
X2-10GB-LR= |
10GBASE-LR X2 Module |
|
X2-10GB-SR= |
10GBASE-SR X2 Module |
|
X2-10GB-LRM= |
10GBASE-LRM X2 Module |
|
X2-10GB-LX4= |
10GBASE-LX4 X2 Module |
|
X2-10GB-CX4= |
10GBASE-CX4 X2 Module |
|
LC to SC Cables for the Cisco Catalyst 3560-E Series |
|
|
CSS5-CABLX-LCSC= |
CSS11500 10-Meter Fiber Single Mode LX LC-to-SC Connectors |
|
CSS5-CABSX-LC= |
CSS11500 10-Meter Fiber Multimode SX LC Connectors |
|
CSS5-CABSX-LCSC= |
CSS11500 10-Meter Fiber Multimode SX LC-to-SC Connectors |
|
Spare Power Cords for the Cisco Catalyst 3560-E Series |
|
|
CAB-AC= |
Power Cord, 110V |
|
CAB-16AWG-AC= |
AC Power cord, 16AWG |
|
CAB-ACA= |
Plug, Power Cord, Australian, 10A |
|
CAB-ACE= |
Power Cord Europe |
|
CAB-ACI= |
Power Cord-Italian |
|
CAB-ACR= |
Power Cord Argentina |
|
CAB-ACS= |
Power Cord for Switzerland |
|
CAB-ACU= |
Power Cord UK |
|
CAB-JPN= |
Power Cord-Japan |
|
CAB-L620P-C13-US= |
Power Cord, 250VAC, 15A, NEMA L6-20 to C13, US |
|
CAB-L620P-C13-JPN= |
Power Cord, 250VAC, 15A, NEMA L6-20 to C13, JAPAN |
|
CAB-IND= |
Power Cord India |
|
CAB-C13-C14-AC |
Power Cord with C14 connector |
|
CAB-SFP-50CM= |
Catalyst 3560-E SFP Interconnect Cable, 50cm |
|
Spare Rack Mount Kits for the Cisco Catalyst 3560-E Series |
|
|
RCKMNT-E-1RU= |
Rack Mount Kit (1RU) for Catalyst 3750-E and 3560-E |
|
Cisco Catalyst 3560-E Relicensing for Used Equipment |
|
|
LL-3560E-IPB= |
IP Base SW Feature set license for Catalyst 3560-E Series |
|
LL-3560E-IPS= |
IP Services SW Feature set license for Catalyst 3560-E Series |
|
Software Application Support Plus Upgrades Technical Services Contract |
|
|
Product Part Number |
Service Contract Number |
|
3560E-IPS-LIC-B |
Catalyst 3560-E IPS Upgrade from IP Base |
|
3560E12D-SLB-QTY |
IP Services for 3560E-12D, upgrade from IP Base |
|
3560E12SD-SLB-QTY |
IP Services for 3560E-12SD, upgrade from IP Base |
Cisco 3560 Series Switch Data Sheet Cisco 3560-E Series Switch Data Sheet
Cisco 3560-X Series Switch Data Sheet Cisco 3560 Series Switch Comparison